Megger MIT510/2 Repair and Calibration by Dynamics Circuit (S) Pte. Ltd.

author Dynamics Circuit S Pte Ltd   3 мес. назад
40 views

0 Like   0 Dislike

Insulation Resistance Test (Includes Line and Neutral Together to Earth and Between Live Conductors)

Students training aid for testing insulation resistance of complete domestic dwelling. Demonstration shows how to set up your Megger MFT tester and carry out an insulation resistance test live conductors (line and neutral) to earth and between live conductors. Test voltage is 500V d.c. and the minimum acceptable value according to BS 7671 is 1 megohms for the whole instillation with further investigation when the reading falls below 2 megohms. Also shows and explains the need to switch both 2 way switches into the other on position and repeat the insulation resistance test. Removing of all loads and leaving switches in the on position. Videos are training aids for City and Guilds (C and G) and EAL courses Level 1, 2 and 3. https://www.facebook.com/gshelectrical/

Setting Up A Megger MFT for Continuity and Insulation Resistance Tests (Setting up a Tester)

Student training aid for setting up a Megger MFT for testing continuity and insulation resistance. Also cover the pre-checks on test leads and the need for a calibration sticker and certificate. Video talks about for the need for on-going accuracy tests and the use of a check box. Videos are training aids for City and Guilds (C and G) and EAL courses Level 1, 2 and 3. https://www.facebook.com/gshelectrical/

9 - Insulation Resistance Global Test - Hull College Electrical

Megger Testing: Tracing Electrical short

Customer reported this unit had tripped the RCD/GFI, I traced the fault and found it was due to a faulty pressure dual switch. The fault took a while to find as the shorted component was connected to the crankcase heater supply via the contactor NC contact, this made it look initially that the fault was one of the motors or the CCH itself.

300sqmm. Cable to test करने का आसान तारीका।BS EEI

Hello friends ajj ki esh video mein ham 300sq.mm. ki cable ka meggar kea sath insulation test karna sekhe gea.esh video ko dekh ke app koi b cable jaise 120sqmm,150,180,and 400 etc ko check kar sakhte hea.for more electrical and instrument related videos ko dekhne ke liye hammare YouTube channel BS EEI ko subscribe kare.

Megger MIT510/2 Repair and Calibration by Dynamics Circuit (S) Pte. Ltd.

5 kV diagnostic insulation resistance tester MIT 510 with Data Storage (Discontinued). The MIT510 increases the functionality by permitting test voltage to be set in any 10 V increment from 50 V to 1 kV, then in 25 V steps all the way to 5 kV.

The testers measure to 15 Tera-ohms, thereby making them fully suitable for critical installation tests and establishment of reliable base data for new high-capital equipment

Receive complete support for your Megger Authorised Service Center, Dynamics Circuit (S) Pte. Ltd. We include a comprehensive warranty with all Megger spares and repairs for your added peace of mind.

An ISO 9001:2015 certified and ISO/IEC 17025 accredited Lab, Dynamics Circuit (S) Pte. Ltd. has highly skilled and qualified workforces which specialize in repairs of High Voltage Test and Measurement Instruments.

Talk to us, the experts!

Dynamics Circuit (S) Pte. Ltd.
15 Yishun Industrial Street 1, #09-28 Win 5,
Singapore 768091.
Contact: (+65) 6754 7024
Email: sales@dynamicscircuit.com
www.dynamicscircuit.com

Comments for video: